MSX® – New differential pressure transmitter for low ranges

The Series MSX Magnesense® Differential Pressure Transmitter combines the stability and versatility of the original Series MS2 Magnesense® II transmitter for use in building control applications.
All pressure ranges can be configured in unidirectional or
bidirectional modes, providing a total of 32 ranges

Read more


VISA/MASTERCARD, PAYPAL,
ANTICIPATED REMITTANCE OR DIRECT
PAYMENT WITH DELIVERY AT OUR
WHAREHOUSE.



CUSTOMER SERVICE: +39.02.6659.5982

SKU Model Description Price Quantity Price for quantity
39109 MSX-W10-PA

Display: no.
Output signal: 4 - 20 mA (2-wire), 0 - 5 VCC, 0 - 10 VCC(3-wire).
Selectable pressure ranges unidirectional:  0 - 25 Pa / 0 - 30 Pa / 0 - 40 Pa / 0 - 50 Pa / 0 -60 Pa / 0- 75 Pa / 0 - 100 Pa / 0 - 125 Pa
Selectable pressure ranges bidirectional :  -25+25 Pa / -30+30 Pa / -40+40 Pa / -50+50 Pa / -60+60 Pa / -75+75 Pa / -100+100 Pa / -125+125 Pa

All pressure ranges can be configured in unidirectional or bidirectional mode
 

88 EUR
1 - 2 : € 88.00
3 - 5 : € 84.48
6 - 10 : € 80.96
11 - 25 : € 77.44
26 - 50 : € 74.80
51 - 99 : € 73.04
39190 MSX-W10-IN-LCD

Display: YES.
Output signal: 4 - 20 mA (2-wire), 0 - 5 VCC, 0 - 10 VCC(3-wire).
Selectable pressure ranges unidirectional:  0 - 25 Pa / 0 - 30 Pa / 0 - 40 Pa / 0 - 50 Pa / 0 -60 Pa / 0- 75 Pa / 0 - 100 Pa / 0 - 125 Pa
Selectable pressure ranges bidirectional :  -25+25 Pa / -30+30 Pa / -40+40 Pa / -50+50 Pa / -60+60 Pa / -75+75 Pa / -100+100 Pa / -125+125 Pa

All pressure ranges can be configured in unidirectional or bidirectional mode
 

125 EUR
1 - 2 : € 125.00
3 - 5 : € 120.00
6 - 10 : € 115.00
11 - 25 : € 110.00
26 - 50 : € 106.25
51 - 99 : € 103.75
39110 MSX-W11-PA

Display: no.
Output signal: 4 - 20 mA (2-wire), 0 - 5 VCC, 0 - 10 VCC(3-wire).
Selectable pressure ranges unidirectional:  0 - 25 Pa / 0 - 40 Pa / 0 - 50 Pa / 0 - 60 Pa / 0 - 100 Pa / 0 - 150 Pa / 0 - 160 Pa / 0 - 250 Pa
Selectable pressure ranges bidirectional :  -25+25 Pa / -40+40 Pa / -50+50 Pa / -60+60 Pa / -100+100 Pa / -150+150 Pa / -160+160 Pa / -250+250 Pa

All pressure ranges can be configured in unidirectional or bidirectional mode
 

88 EUR
1 - 2 : € 88.00
3 - 5 : € 84.48
6 - 10 : € 80.96
11 - 25 : € 77.44
26 - 50 : € 74.80
51 - 99 : € 73.04
39191 MSX-W11-IN-LCD

Display: YES
Output signal: 4 - 20 mA (2-wire), 0 - 5 VCC, 0 - 10 VCC(3-wire).
Selectable pressure ranges unidirectional:  0 - 25 Pa / 0 - 40 Pa / 0 - 50 Pa / 0 - 60 Pa / 0 - 100 Pa / 0 - 150 Pa / 0 - 160 Pa / 0 - 250 Pa
Selectable pressure ranges bidirectional :  -25+25 Pa / -40+40 Pa / -50+50 Pa / -60+60 Pa / -100+100 Pa / -150+150 Pa / -160+160 Pa / -250+250 Pa

All pressure ranges can be configured in unidirectional or bidirectional mode
 

125 EUR
1 - 2 : € 125.00
3 - 5 : € 120.00
6 - 10 : € 115.00
11 - 25 : € 110.00
26 - 50 : € 106.25
51 - 99 : € 103.75
39111 MSX-W12-PA

Display: no.
Output signal: 4 - 20 mA (2-wire), 0 - 5 VCC, 0 - 10 VCC(3-wire).
Selectable pressure ranges unidirectional:  0 - 250 Pa / 0 - 300 Pa / 0 - 400 Pa / 0 - 500 Pa / 0 -600 Pa / 0- 750 Pa / 0 - 1000 Pa / 0 - 1250 Pa
Selectable pressure ranges bidirectional :  -250+250 Pa / -300+300 Pa / -400+400 Pa / -500+500 Pa / -600+600 Pa / -750+750 Pa / -1000+1000 Pa / -1250+1250 Pa

All pressure ranges can be configured in unidirectional or bidirectional mode
 

88 EUR
1 - 2 : € 88.00
3 - 5 : € 84.48
6 - 10 : € 80.96
11 - 25 : € 77.44
26 - 50 : € 74.80
51 - 99 : € 73.04
39192 MSX-W12-IN-LCD

Display: YES
Output signal: 4 - 20 mA (2-wire), 0 - 5 VCC, 0 - 10 VCC(3-wire).
Selectable pressure ranges unidirectional:  0 - 250 Pa / 0 - 300 Pa / 0 - 400 Pa / 0 - 500 Pa / 0 -600 Pa / 0- 750 Pa / 0 - 1000 Pa / 0 - 1250 Pa
Selectable pressure ranges bidirectional :  -250+250 Pa / -300+300 Pa / -400+400 Pa / -500+500 Pa / -600+600 Pa / -750+750 Pa / -1000+1000 Pa / -1250+1250 Pa

All pressure ranges can be configured in unidirectional or bidirectional mode
 

125 EUR
1 - 2 : € 125.00
3 - 5 : € 120.00
6 - 10 : € 115.00
11 - 25 : € 110.00
26 - 50 : € 106.25
51 - 99 : € 103.75
39112 MSX-W13-PA

Display: no.
Output signal: 4 - 20 mA (2-wire), 0 - 5 VCC, 0 - 10 VCC(3-wire).
Selectable pressure ranges unidirectional:  0 - 1000 Pa / 0 - 1500 Pa / 0 - 2000 Pa / 0 - 2500 Pa / 0 - 3000 Pa / 0 - 4000 Pa / 0 - 5000 Pa / 0 - 7000 Pa
Selectable pressure ranges bidirectional :  -1000+1000 Pa / -1500+1500 Pa / -2000+2000 Pa / -2500+2500 Pa / -3000+3000 Pa / -4000+4000 Pa / -5000+15000 Pa / -7000+7000 Pa

All pressure ranges can be configured in unidirectional or bidirectional mode
 

88 EUR
1 - 2 : € 88.00
3 - 5 : € 84.48
6 - 10 : € 80.96
11 - 25 : € 77.44
26 - 50 : € 74.80
51 - 99 : € 73.04
39193 MSX-W13-IN-LCD

Display: YES
Output signal: 4 - 20 mA (2-wire), 0 - 5 VCC, 0 - 10 VCC(3-wire).
Selectable pressure ranges unidirectional:  0 - 1000 Pa / 0 - 1500 Pa / 0 - 2000 Pa / 0 - 2500 Pa / 0 - 3000 Pa / 0 - 4000 Pa / 0 - 5000 Pa / 0 - 7000 Pa
Selectable pressure ranges bidirectional :  -1000+1000 Pa / -1500+1500 Pa / -2000+2000 Pa / -2500+2500 Pa / -3000+3000 Pa / -4000+4000 Pa / -5000+15000 Pa / -7000+7000 Pa

All pressure ranges can be configured in unidirectional or bidirectional mode
 

125 EUR
1 - 2 : € 125.00
3 - 5 : € 120.00
6 - 10 : € 115.00
11 - 25 : € 110.00
26 - 50 : € 106.25
51 - 99 : € 103.75

Description

The Series MSX Magnesense® Differential Pressure Transmitter combines the stability and versatility of the original Series MS2 Magnesense® II transmitter for use in building control applications. The MSX simplifies the ordering process to deliver the desired configuration, which reduces product setup time. Pressure ranges are available in Pa, mm w.c., and in w.c.

All pressure ranges can be configured in unidirectional or
bidirectional modes, providing a total of 32 ranges.

The MSX transmitter can provide
a linear pressure output or a linear velocity output with the square root extraction from the transmitter. Additional parameters have been included to expand the square root capability for calculating flow. Dual voltage and milliamp output signals can be used to provide both control and equipment output signal verification

 

SPECIFICATIONS

Service:
Air and non-combustible, compatible gases.
Wetted Materials: Consult factory.
Accuracy: ±1% FSO.Stability: ±1% FSO/year.
Temperature Limits: -4 to 158°F (-20 to 70°C).
Pressure Limits: Ranges 0 and 1: 3.6 psi max operation, 6 psi burst;
                            
Ranges 2 and 3: 6 psi max operation, 6 psi burst.
Power Requirements: 10-36 VDC (2-wire), 17-36 VDC or isolated 21.6-33 VAC (3-wire).
Output Signals: 4-20 mA (2-wire); 0-10 V or 0-5 V selectable (3-wire).
Response Time: Instantaneous (default) or 3 s (selectable).
Zero and Span Adjustments: Digital push-button
Loop Resistance:
Current output: 0-1250 Ω max; Voltage output: min. load resistance 1 kΩ.
Current Consumption: 21 mA max continuous.
Electrical Connections: 4-wire removable European style terminal block for 16 to 26 AWG.
Electrical Entry: 1/2 ̋ NPS thread.Display (optional): 4 digit LCD.
Process Connections: 1/8 ̋, 3/16 ̋, 1/4 ̋, 5 mm, and 6 mm ID flexible tubing.
Enclosure Rating: NEMA 4X (IP66), UL 2043 (Plenum), UL94 V-0.
Mounting Orientation: Pressure sensor measurement unaffected by orientation.
Weight: 8.0 oz (230 g).
Agency Approvals: CE
 

Documentation

Accessories

SKU Model Description Price Quantity
18172
Differential Pressure Certificate Ref. UKAS/ACCREDIA

UKAS/ACCREDIA Traceable Certificate for DIFFERENTIAL PRESSURE on 3-point check: low range, mid-scale, full scale.

€35.00
10674
A-481
Installer kit, (includes 2 static pressure tips and PVC tubing).
€6.00

Similar products

APRE-2000G - Smart differential pressure transmitter

From few Pascals up to 10 KPa Zero elevation and programmable filter.
Programmable linear or quadratic output. Analog output 4 ... 20mA + HART protocol.

APR-2000ALW - Smart differential pressure transmitter

SMART industrial differential pressure transmitter. Output: 4-20 mA + HART. Programming of zero value, span, characteristics, damping, using front buttons on the display.

APRE 2000G/N - Smart differential pressure transmitter

Execution in IP 65 plastic case. Programmable linear or quadratic output. Output: 4 ... 20 mA + HART protocol. Programmable via HART protocol and with front keys on the instrument.